- Home
- Products
- Open frame ATX output
- MPD-810H-1
MPD-810H-1




FEATURES
○ IU Chassis design for thermal conduction
○ Fully isolated primary to secondary; primary to earth ground
Models & Ratings
Model Number | Wattage | Output Voltage | Output Current |
---|---|---|---|
MPD-810H-1 | 85/120W | +5V +12V -12V +3.3V +5Vsb |
2.5A 5A 0.5A 2.5A 0.75A |
Summary
Characteristic | Minimum | Typical | Maximum | Units | Notes & Conditions |
---|---|---|---|---|---|
Input Range | 10 | 12/24 | 30 | VDC | |
Efficiency | 70 | % | Measuring at nominal line and rated load. | ||
Operation Temperature | 0 | +50 | ºC | Output power is 120 watts forced air cooling, 85 watts convection cooling | |
Weight | |||||
Dimensions | 152.4 x 83.8 x 38 mm, tolerance +/- 0.4mm | ||||
EMC | EN 55022, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4 | ||||
Safety Approvals | UL 60950-1, CAN/CSA C22.2 No.60950-1 |