- Home
- Products
- Open frame Single & Multi-output
- MPI-G500 Series
MPI-G500 Series




FEATURES
○ Optional +5Vsb and remote on/off function.
○ Compact size 3 x 5 inch and low profile
○ Design to meet EN 60335-1
○ ITE safety standard IEC 62368-1, UL 62368-1, LVD 62368
○ O/P 500W with forced air, 300W with convection-cooled
○ Active PFC meet EN 61000-3-2 Class D and EN 61000-3-3.
Models & Ratings
Model Number | Wattage | Output Voltage | Output Current |
---|---|---|---|
MPI-G503 | 300W/ 500W | +12V | 25A / 41.6A |
MPI-G505 | 300W / 500W | +24V | 12.5A / 20.8A |
MPI-G506 | 300W / 500W | +48V | 6.25A / 10.4A |
Summary
Characteristic | Minimum | Typical | Maximum | Units | Notes & Conditions |
---|---|---|---|---|---|
EMC | EN 55032, CISPR 32 & FCC Part 15, EN 61000-3-2, EN 61000-3-3, EN 61204-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 | ||||
Efficiency | 94 | % | At input 230VAC, rated load, above 1hr warm up | ||
Dimensions | 127.0 (L) x76.2 (W) x 38.0(H) mm, Tolerance +/- 0.4mm. | ||||
Input Frequency | 47 | 50/60 | 63 | Hz | AC input |
Safety Approvals | UL 62368-1, 2nd Edition, CSA C22.2 No. 62368-1-14, 2nd Edition CE 62368. EN 60335-1, Design to meet | ||||
Weight | 420 | g | |||
Operating Temperature | -20 | 80 | °C | ||
Input Range | 80 | 115/230 | 264 | VAC | Universal input range |